127
Reference Manual
00809-0100-4811, Rev DA
Appendix A: Reference Data
January 2015
Reference Data
Table A-3. Transition Zones
Figure A-12. Transition Zones
Dielectric
constant
Rigid single
lead /
segmented
rigid single
lead
Flexible single
lead
Coaxial Rigid twin
lead
Flexible twin
lead
Upper
(1)
transition
zone
(1) The distance from the upper reference point where measurements have reduced accuracy.
80 4 in. (10 cm) 5.9 in. (15 cm) 4 in. (10 cm) 4 in. (10 cm) 5.9 in. (15 cm)
2 4 in. (10 cm) 20 in. (50 cm) 4 in. (10 cm) 4 in. (10 cm) 8 in. (20 cm)
Lower
(2)
transition
zone
(2) The distance from the lower reference point where measurements have reduced accuracy.
80 2 in. (5 cm) 2 in. (5 cm)
(3)
(4)
(3) The measuring range for the PTFE covered Flexible Single Lead probe includes the weight when measuring on a high dielectric media.
1.2 in. (3 cm) 2 in. (5 cm) 2 in. (5 cm
(4)
)
(4) Note that the weight length or chuck fastening length adds to non-measurable area and is not included in the diagram. See “Dimensional drawings”
on page 142
.
2 4 in. (10 cm)
(5)
(5) When using a metallic centering disc, the lower transition zone is 8 in. (20 cm), including weight if applicable. When using a PTFE centering disc, the lower
transition zone is not affected.
Note
The 4-20 mA set points are recommended to be configured between the transition zones,
within the measuring range.
6.3 in. (16 cm) - long
weight, short weight,
and chuck
(4)(5)
2 in. (5 cm) 2.8 in. (7 cm) 5.9 in. (15 cm)
(4)(5)
Upper reference point
Upper transition zone
Maximum recommended
measuring range
Lower transition zone
Lower reference point
Lower transition zone